logo
Casa > prodotti >
Indicatore di guasti del cavo
>
Precision and Reliability Cable Fault Simulation Device for Simulating All Types of Faults in Power Cables

Precision and Reliability Cable Fault Simulation Device for Simulating All Types of Faults in Power Cables

Dettagli del prodotto:
Luogo di origine: Xi'an
Marca: XZH TEST
Certificazione: CE
Numero di modello: XHFZ510-B2
Informazione dettagliata
Luogo di origine:
Xi'an
Marca:
XZH TEST
Certificazione:
CE
Numero di modello:
XHFZ510-B2
Metodo di messa a terra:
Terreno di lavoro, terreno di prova
Tempo di lavoro continuo:
ore ≥8
Temperatura ambiente:
-40 da ℃ a +80 ℃
Evidenziare:

High Light

Evidenziare:

Precision Cable Fault Simulation Device

,

Reliable Cable Fault Locator

,

Simulate All Types of Faults Power Cable Tester

Trading Information
Quantità di ordine minimo:
1 set
Imballaggi particolari:
Imballaggio in legno
Tempi di consegna:
5-8 giorni lavorativi
Termini di pagamento:
T/T
Capacità di alimentazione:
3000 unità/anno
Descrizione di prodotto
XHFZ510-B2
Urbanization and rising electricity demand promote the replacement of overhead lines with cables. Training for cable fault detection personnel is a persistent challenge. Our self-developed electrical test simulation training system, built on decades of expertise, simulates all cable faults to support seamless training.
Technical Parameters
High-voltage cable length ≥300 meters (coaxial cable)
High-voltage cable outer diameter ≥φ12mm
High-voltage cable main insulation withstand voltage ≥30kVDC
High-voltage cable outer sheath withstand voltage ≥5kVDC
Number of high-voltage cable faults ≥4, with ≥1 fault at a T-joint


Panel Introduction


Precision and Reliability Cable Fault Simulation Device for Simulating All Types of Faults in Power Cables 0

Test Terminals:

1) Fault Phase: Connection port for the fault phase during high-voltage bridge fault testing;

2) Reference Phase: Connection port for the reference phase during high-voltage bridge fault testing;

3) Test Ground: Connection port for the test ground during high-voltage bridge fault testing;

4) Fault Point Proportion: Adjustment knob for the fault point proportion during high-voltage bridge fault testing;

5) Main Insulation: Connection port for the cable core when the cable fault tester tests for main insulation faults;

6) Test Ground: Connection port for the cable shielding layer when the cable fault tester tests for main insulation faults;

7) Grounding Post: Instrument grounding point for safety protection.

Precision and Reliability Cable Fault Simulation Device for Simulating All Types of Faults in Power Cables 1