High Voltage Cable Sheath Fault Locator with Rough Measurement and ≥7500V for Cable Sheath Testing

High Voltage Cable Sheath Fault Locator with Rough Measurement and ≥7500V for Cable Sheath Testing

Dettagli del prodotto:
Luogo di origine: Xi'an ShanXi Cina
Marca: XZH TEST
Certificazione: ISO/CE
Numero di modello: XHHG521A
Informazione dettagliata
Luogo di origine:
Xi'an ShanXi Cina
Marca:
XZH TEST
Certificazione:
ISO/CE
Numero di modello:
XHHG521A
Evidenziare:

High Light

Evidenziare:

≥7500V Cable Sheath Fault Locator

,

Rough Measurement Cable Fault Locator

,

Cable Sheath Testing Cable Fault Detector

Trading Information
Quantità di ordine minimo:
1 set
Imballaggi particolari:
Imballaggio in legno
Tempi di consegna:
5-8 giorni lavorativi
Termini di pagamento:
T/T
Capacità di alimentazione:
3000 unità/anno
Descrizione di prodotto
XHHG521A
Suitable for coarse measurement of fault distance in cable outer sheath
Key Features
  • Designed for detecting faults in cable sheaths
  • Performs rough measurement of fault locations
  • Professional-grade equipment for industrial applications
  • Adjustable output voltage; High accuracy and stability;
  • Employs a high-sensitivity amplifier and galvanometer for balance indication;
  • Zero-position protection; Automatic fault point testing, while retaining manual testing functionality;

High Voltage Cable Sheath Fault Locator with Rough Measurement and ≥7500V for Cable Sheath Testing 0

The principle of the bridge method for cable fault location is as follows: Short-circuit the faulty phase and the non-faulty phase of the cable under test. Connect the two arms of the bridge to the faulty phase and the non-faulty phase respectively. Adjust an adjustable resistor on each arm of the bridge to balance it. Using the proportional relationship and the known cable length, the fault distance can be calculated. The advantages of the bridge method for cable fault location are its simplicity and accuracy meeting the requirements of on-site engineering testing. It is particularly convenient for measuring two-phase short-circuit faults in cable lines. Using the Murray bridge to locate the breakdown point is a classic method, convenient and accurate. The bridge method is based on the premise that the resistance of the conductor (or shielding layer) is uniform and proportional to its length. The following figure shows a typical application:

High Voltage Cable Sheath Fault Locator with Rough Measurement and ≥7500V for Cable Sheath Testing 1