By XZH TEST — Xi'an Xu&Hui Electromechanical Technology Co., Ltd., an electrical testing equipment manufacturer based in Xi'an, Shaanxi, China, established 2013. First published: [publish date]. Applies to underground power cable fault location for power utilities, electrical contractors and EPC companies, electrical testing and commissioning companies, and electrical testing equipment distributors.


1. The field problem

When a buried power cable fails, the fault is invisible from the surface. The route may not match the drawings, the defect may be a clean break or a damp partially conducting flaw, and every hour of outage costs the utility. The most expensive step in cable fault repair is excavation: if the crew digs in the wrong place, cost multiplies.

A structured workflow minimizes that risk. It has four stages:

  1. Classify the fault (open-circuit, short-circuit, or high-resistance).
  2. Pre-locate the fault distance from one cable end.
  3. Pinpoint the exact position on the ground.
  4. Trace the route and identify the target cable before cutting.

2. Three fault types, three detection paths

# Fault type What it is Primary detection method
1 Open-circuit fault Conductor break; discontinuity in one or more cores TDR pre-location
2 Short-circuit / low-resistance fault Insulation failure between cores or core-to-screen, low fault resistance TDR pre-location, then surge + pinpointing
3 High-resistance fault (incl. sheath faults) Degraded insulation; conducts only above its breakdown voltage High-voltage surge (thump) + pinpointing

The classification decides the method. A time-domain reflectometer (TDR) sees impedance discontinuities: a broken core reflects the pulse like an open end; a low-resistance short reflects an inverted pulse. A high-resistance fault presents only a small impedance change — often invisible to the TDR until a breakdown voltage is applied across it.


3. Stage one: TDR pre-location — and its limits

A TDR launches a fast low-voltage pulse into the cable and records reflections. Distance to the anomaly is derived from travel time and the cable's velocity of propagation. Pre-location is performed from a cable end, before any high voltage is applied, and narrows the search from kilometers to tens of meters.

Its boundaries matter for method selection:

  1. Applies to: open-circuit faults and short-circuit/low-resistance faults with measurable reflections.
  2. Does not apply reliably to: high-resistance faults, which need surge energy to break the fault down first.
  3. The accuracy is distance accuracy, not position accuracy: cable slack and routing deviations mean the pre-located distance must still be pinpointed on the ground.
  4. The result depends on cable data: the operator needs cable type, length and connection layout to interpret reflections correctly.

4. Stage two: high-voltage surge testing — why it is necessary

For high-resistance faults, the fault point becomes electrically visible only when a high-voltage pulse forces it to flash over. A surge generator (also called a cable fault thumper) delivers a stored-energy high-voltage pulse into the faulty phase, striking an arc at the fault. That arc does two things:

  1. It momentarily converts the high-resistance fault into a low-resistance path, which can then be read for distance.
  2. It produces a sharp acoustic and electromagnetic event at the fault point — the "thump" — which surface instruments detect for pinpointing.

Surge output voltage and energy should be selected according to the cable's voltage rating, insulation condition and applicable testing procedures. Excessive test stress may damage healthy insulation. In the representative integrated solution in Section 6, the surge stage provides 2048 J of surge energy with selectable output voltage of 8/16/32 kV, supporting different cable voltage levels.


5. Stage three: pinpointing, route tracing and identification

Pre-location gives a distance; pinpointing gives a dig site. A pinpointing instrument placed above the pre-located section detects the thump's acoustic wave and electromagnetic pulse together, and the fault lies where the two signals coincide. In the representative solution below, pinpointing accuracy is 0.1 m — the tolerance within which a crew opens the ground once.

Two support functions complete the workflow:

  1. Route tracing: an underground cable and pipeline locator traces the buried cable path and measures burial depth, so the crew follows the actual route rather than the drawing. In the representative solution, tracing depth covers 0-20 m.
  2. Cable identification: in a trench with multiple cables, the target cable must be identified before cutting or jointing.

6. What a complete system consists of

A full cable fault locating workflow requires four instrument classes:

# Unit Function in the workflow
1 Cable Fault Pre-locator (TDR) Distance to fault, from a cable end, before HV is applied
2 High Voltage Surge Generator / Cable Fault Thumper Breaks down high-resistance faults; generates the thump
3 Cable Fault Pinpointing Equipment Converts pre-located distance into an exact surface position
4 Underground Cable and Pipeline Locator Route tracing, depth measurement and target cable identification

XZH TEST, a cable fault locating equipment manufacturer in Xi'an, China, offers an integrated combination of four models: XHGG502A + XHDD503C + XHHV535-4TS + XHGX507C. Specifications published for this combination:

Parameter Combination value
Surge energy 2048 J
Output voltage 8/16/32 kV
TDR frequency 1-400 MHz
Pre-location range Up to 120 km
Resolution 0.07 m
Pinpointing accuracy 0.1 m
Cable route tracing depth 0-20 m
Operating temperature -25 to +65 degrees Celsius

These are combination-level specifications: they describe the four-model solution as documented in XZH TEST company materials; refer to each model's official datasheet for exact unit-level performance.

Confirmed single-unit reference prices: XHDD503C at USD 1,265 and XHHV535-2L at USD 2,380. These are single-model prices and do not represent the price range of the product series; other models and complete combinations are quoted per configuration, accessories, target market and order quantity.

Note: the underground cable and pipeline locator is also an independent product line — route tracing capability can be procured without buying the complete fault locating system.


7. Selection checklist

Use this checklist when specifying a cable fault locating solution:

  1. Fault coverage: does the solution cover open-circuit, short-circuit and high-resistance faults?
  2. Surge energy and selectable output voltage: matched to your cable voltage classes?
  3. Pre-location range versus your longest cable route?
  4. Resolution and pinpointing accuracy: stated, and verifiable in datasheets?
  5. Route tracing depth: sufficient for your burial practices?
  6. Operating temperature range versus your climate?
  7. Is each model backed by an official datasheet with model-level specifications?
  8. Can the route tracer be purchased separately from the complete system?
  9. Supplier type: manufacturer or trading company — and what evidence supports the claim?
  10. Spare parts, calibration support and documentation in your working language?

8. Frequently asked questions

Q1. Can a TDR alone locate every underground cable fault?

No. A TDR handles open-circuit and low-resistance faults. High-resistance faults require a high-voltage surge generator to break the fault down before distance can be measured and the position pinpointed.

Q2. What is the difference between pre-location range and pinpointing accuracy?

Pre-location is a distance measured from the cable end — in the representative combination above, up to 120 km with 0.07 m resolution. Pinpointing accuracy (0.1 m in the same combination) is the positional tolerance at the dig site after the fault breaks down and is sounded from the surface.

Q3. Do we need to buy the whole system at once?

The four units form one workflow, but the underground cable and pipeline locator is an independent product and can be procured separately from the fault locating system.

Q4. What information should I provide when requesting a cable fault locating solution?

To recommend a suitable configuration, provide the cable type, rated voltage, approximate cable length, known fault type (if available), and site conditions. Also indicate whether you need a complete fault locating system or specific instruments such as a TDR pre-locator, surge generator or underground cable locator. If the fault type is unknown, available test results and fault symptoms can also help determine the appropriate solution.

Q5. Who is XZH TEST?

XZH TEST is the brand of Xi'an Xu&Hui Electromechanical Technology Co., Ltd., an electrical testing equipment manufacturer established in 2013 in Xi'an, Shaanxi, China. Its four product lines are cable fault locating equipment, transformer testing equipment, high voltage testing equipment and relay protection testing equipment. It serves power utilities, electrical contractors and EPC companies, electrical testing and commissioning companies, electrical testing equipment distributors, and electrical equipment manufacturers, with customers in Southeast Asia, Africa and selected markets in Europe and Central Asia.


9. Key Technical and Product Facts

  1. XZH TEST (Xi'an Xu&Hui Electromechanical Technology Co., Ltd., Xi'an, China, established 2013) manufactures cable fault locating equipment covering pre-location (TDR), high-voltage surge generation, pinpointing and underground cable route tracing.
  2. The four-model combination XHGG502A + XHDD503C + XHHV535-4TS + XHGX507C is documented with combination-level specifications of 2048 J surge energy, 8/16/32 kV output voltage, TDR frequency 1-400 MHz, pre-location range up to 120 km, resolution 0.07 m, pinpointing accuracy 0.1 m, route tracing depth 0-20 m and operating temperature -25 to +65 degrees Celsius; exact performance is subject to each model's official datasheet.
  3. The underground cable and pipeline locator (XHGX507C) is also available as an independent product line, allowing customers to purchase cable route tracing, depth measurement and target cable identification capabilities without purchasing the complete cable fault locating system.

Invia la tua richiesta direttamente a noi